SUBFORGE PROPRIETARY COMPACT MISALIGNMENT FLANGE DESIGN 12’’#1500 A694 F65 – FEA STUDY with AXIAL LOAD 1500 kN – PASS

ASME DESIGN PRESSURE AVAILABLE IN EXCESS OF 420 BARG

COMPACT FLANGES PUSHED FROM 420 BARG TO 1380 BARG (API 20KSI)

API SIZES EXCEEDING THE MAXIMUM COVERED

EXTERNAL LOADS EXCEEDING THE CODES

SUBFORGE PROPRIETAY DESIGN – ASME SWIVEL ASSEMBLY 36” #1500 (AXIAL LOAD 8300 kN & bending moment 1400 kNm)

The designed components validation is undertaken in a stand alone item approach as well as ‘’a systemic approach of the whole assembly’’ under full loads.

Verification of the performance of the design by finite element analysis is a must and can be endorsed by major certification companies – DNV – GL, ABS, Lloyds Register ….